Southeast Church Supply


Since 1979 providing churches with baptistries, steeples, pews, kneelers, cushions, altar candles, paschal candles, candlesticks, tabernacles, offering boxes, baptistry heaters and more!

FREE SHIPPING!
Orders Over $150 that ship via UPS in the USA
(Excludes AK and HI)
Click Here For More Info




SecurityMetrics for PCI Compliance, QSA, IDS, Penetration Testing, Forensics, and Vulnerability Assessment

 

ChurchProducts.com 

has spent over

$100,000

since 2015 in

support of

these groups:

We Support Food for the Poor

We Support SIFAT

We Support Campus Crusade

Support the Jesus Film

We support the Little Sisters of the Poor Sacred Heart residence in Mobile, Alabama.

We support Catholic Relief Services

Support Christian Martyrs and their Families

Donate Now to Food for the Poor

Tell a friend about this product
Your Name:
Your Email:
Your Friend's Name:
Your Friend's Email:
Subject:
Include a Note:
Hover over image to zoom
FSI-SB10 - Fiberglass Church Steeple Height 10 Foot
Fiberglass Church Steeple Height 10 Foot
 

STANDARD STEEPLE SPECIFICATIONS

  • Anchoring members are all steel
  • We use low emission Environmentally friendly gel coats
  • Easy installation with simple bolt-together connection
  • Polyester wall is Fiberglass reinforced with a flexural strength up to 29,000 psi
  • Certified to withstand wind speeds up to 120 mph
  • Weather-resistant seal with collar-to-collar fit and overhanging lip
  • Available in Bone or White Standard. Other colors quoted on request.
  • Allow 4-6 weeks for most orders to deliver.
FS-SO - STEEPLE OPTIONS -
Add a SPIRE CROSS (and/or a DECORATIVE BALL) to the point of the spire.

spire cross for steeple

ROOF INFORMATION


Roof Pitch
To determine the pitch of your roof, place a level against the roof as shown below. From the point where the level touches the roof, measure out 12 inches. From this point, measure the distance, in inches, down to the roof. This number will be the first number in the roof pitch. The second number will always be 12. For example, the roof pitch pictured here would be expressed as 5" on 12" or 5/12


NOTE We do not cut the pitch.You cut the pitch onsite using a simple cross stick template.
We require the pitch for proper placement of internal supports.
PLEASE ENTER IN BOX BELOW
(1) ROOF SLOPE
(2) MATERIAL (shingle, metal, etc.)
(3) CROSS DIRECTION (A or B)
FS-LP - LIGHTENING PROTECTION consists of a copper arial (top of steeple) attached to copper cable running through the interior of the steeple to the steeple base. You will also need additional grounding cable to run from the base to the grounding location. Electrical code requires that your electrician ground the unit. Lightening protection can provide protection in the event of a lightening strike, but is no guarantee that your steeple or building will not be damaged or destroyed by lightening.


To Order: Enter quantity of "1" in the Lightening Protection box

Enter lineal feet needed in the "extra cable" box.
DELIVERY -


Steeple Shipping/Delivery

 

Delivery pricing is based on past experience and should be acccurate for most orders. Some situations and locations may be more than the price shown - delivery pricing listed below is subject to approval. In the unlikley event delivery will be higher than listed, we will contact you before processing your order and you can approve the higher costs or cancel your order without penalty.


Be sure to check the appropriate extra delivery charges if applicable.

See BELOW "Click Here for Important Delivery Information" before you place your order.



 
Price per Each






Wind Loading: Different areas of the country have different wind loading requirements. Coastal areas usually have requirements that steeples meet 155mph+ wind loading requirements. It is the churches responsibility to determine the local requirements. Our standard steeples meet 120mph wind loading so if you require 155+ please email us before ordering for a quote to make your steeple meet 155+ requirements (this usually involves engineering reports and additional bracking). 

STANDARD STEEPLE SPECIFICATIONS

  • Anchoring members are all steel
  • We use low emission Environmentally friendly gel coats
  • Easy installation with simple bolt-together connection
  • Polyester wall is Fiberglass reinforced with a flexural strength up to 29,000 psi
  • Certified to withstand wind speeds up to 120 mph
  • Weather-resistant seal with collar-to-collar fit and overhanging lip
GUIDE SPECIFICATIONS - STEEPLES & CUPOLAS FIBERGLASS SPECIALTIES, INC. HENDERSON, TEXAS

DESCRIPTION Steeple (or cupola) shall be prefabricated of fiberglass reinforced polyester (FRP)

MATERIALS. Fiberglass reinforced polyester shall have properties within the following ranges: Flexural Strength ASTM D-790 10,000 - 24,000 psi Tensile Strength ASTM D-638 10,000 - 14,000 psi Compressive Strength ASTM D-695 18,000 – 27,000 psi B. Unit shall be adequately reinforced to prevent warping and buckling of surface panels, with adequate strength to withstand wind speeds of up to 120 mph. All anchoring members shall be steel. C. All components shall be prefit at the factory to assure proper fit and ease of installation.

FINISH: (Standard units): Unit shall have smooth, high gloss polyester gel-coat finish, in white or special color

NSTALLATION Installation should be by an experienced contractor using anchor points provided by manufacturer and using anchor rods or bolts as specified

WARRANTY The manufacturer shall provide a written ten (10) year warranty (2 years for custom designs) against defects in materials and workmanship.